HS ldler Type sensor
P/N: S24HSIT-01
Idler Sensor 1.5 & 1.75 Dbl
Our products are customized to suit your needs!
| Name | Manufacturer | Type |
| Idlers | HS Sensor | Customized processing |
| Hydraulic cylinder | HS Sensor | Customized processing |
| Hydraulic tubing | HS Sensor | Specification adaptation |
| Frame | HS Sensor | Customized processing |

Integrated Radar Level Sensor
P/N: S24IRL-VG-01
Radar level sensor-4… 20 mA/HART – Two-wire, rod, and rope measuring probes TDR sensors- measures maintenance-free all kinds of liquids, even in applications with vapor, buildup foam generation, and condensation.
Our products are customized to suit your needs!
| Features | |
| Manufacturer | VEGA |
| Probe Length | 11500mm |
| Measuring accuracy | ± 2 mm |
| Certificate | ATEX , UKEX |
| Process Temperature | -40-150°C |
| Electronics | Two-wire 4 … 20 mA/HART |
| Power Supply | 9.6 … 35 V DC |
| Protection | IP66/67 |
| Material | Exchangeable cable (ø2mm) with gravity weight /316 |
| Measuring accuracy | ± 2 mm |
| Cable entry / Connection | M20x1.5 / Cable gland PA black (ø5-9mm) |
| Level Sensor Brackets Base | Custom |
Integrated Ultrasonic Level sensor
P/N: S24IUL-SM-01/02
Integral small range ultrasonic liquid level meter. The two-wire system, 4-20 mA circuit power supply, is suitable for liquids in open or closed containers. Its body size has a maximum range of 5 meters.
| Features | |
| Manufacturer | SIEMENS |
| Input | Measuring range Frequency: 0.25 … 5 m/12m(0.8 … 16.4 ft) |
| Frequency: 54 kHz | |
| Output | 4 … 20 mA, Proportional/ inversely proportional, 600 Ω in the loop at 24 V DC |
| Power Supply | 12 … 30 V DC, 0.1 A surge 0.75 W (25 mA at 24 V DC) |
| Certificate | CSA, ATEX , UKEX, IECEx , NEPSI Ex |
| Accuracy | Error in measurement:0.25 % of measuring range (in air) |
| Resolution: 3mm(0.125 inch) | |
| Beam Angle | 12° |
| Ambient Temperature | Standard: -40 … +60 °C (-40 … +140 °F) |
| Metallic mounting: -20 … +60 °C (-4 … +140 °F) | |
| Weight | 1.3 kg (2.9 lb) |
| Material | Electronics enclosure • Transducer: PBT |
| Transducer: PVDF copolymer | |
| Degree Of Protection Process Connection | IP68 / NEMA 6 / TYPE 6 |
| 2″ NPT [(Taper), ASME B1.20.1] • R 2″ [(BSPT), EN 10226] | |
| G 2″ [(BSPP), EN ISO 228-1] | |
| 4″ sanitary | |
| Flange Adapter Cable Inlet | 3″ Universal (fits DN 65, PN 10 and 3″ ASME) 1 inlet for M20, optional 1/2″ NPT |
| Level Sensor Brackets Base | Custom |
Mud logging -Flow Sensor
P/N: S24MF-HH-001/020
Mud Flow Sensor Assembly: Included mounting bracket, blind plate, gland, etc.
Our products are customized to suit your needs!
| Manufacturer | Hohner |
| Output | 4…20 mA 2 wire current loop output |
| Precision | 8 absolute bits / 256 steps、 |
| Per the 90 degrees within 16mA | |
| Equivalent to 1 degree has 0.177mA、0.177mA has 2.84 steps | |
| Operating temp | Operating temp: – 20 …+60℃ |
| Weight | 26 lbs (12 kg) |
| Protection | IP 66 / X7 M |
| Materials Encoder | Stainless Steel |
| Material Chassis | Stainless Steel |
| Material Paddles | Stainless Steel |
| Material Spring | Stainless Steel |
| Pressure Rating | 5 bar |
| Note | Common design of mounting base. |
| Certification | Zone 0 Ex ia IIC Certified |
| CE,ATEX, IECEx, CSA,EAC |
Pressure Transmitter
P/N: S24EH-TU-00500
Pressure transmitter: (4~20mA),500PSI
Our products are customized to suit your needs!
| Features | |
| Pressure Range | Relative pressure : 0…500 psi |
| Admissible overpressure: ≤ 120 bar | |
| Burst pressure: ≥240 bar | |
| Response time: <2 ms, typ. 1 ms | |
| Long-term stability: 0.25% FS, according to IEC EN 60770-1 | |
| Power Supply | Operating voltage:10…30 VDC |
| Current consumption: ≤23 mA | |
| Short-circuit/reverse polarity protection: yes / yes | |
| Protection type and class: IP67 / III | |
| Insulation voltage: 750 VDC | |
| Outputs | Output 1: Analog output |
| Analog Output | Current output: 4…20 mA |
| Operating range: 4…20 mA (2-wire) | |
| Load:≤(Supply voltage -10)/20 kΩ | |
| Resolution: <±0.1 % FS | |
| Accuracy LHR: ± 0.3 % FS BSL | |
| Temperature Behavior | Medium temperature: -30…+120 °C |
| Temperature coefficient: ± 0.2 % of full scale/10 K | |
| Ambient Conditions | Ambient temperature: -25…+85 °C |
| Storage temperature: -50…+100 °C | |
| Vibration resistance:20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15mm acc. to IEC 68-2-6 | |
| Shock resistance:100 g, 11 ms, half sinusoidal curve, all 6 directions, | |
| Free fall from 1 m onto concrete (6x) , acc. to IEC68-2-27 | |
For intrinsically safe applications, the values specified in the corresponding EX certificates (ATEX, IECEX,UL etc.) apply.
Ex approval acc. to conformity certificate: SEV 16 ATEX 0145
Application area: II 1/2 GD
Ignition protection category: Gas Ex ia IIC; dust Ex ia IIIC
| HS P/N | Pressure |
| S24EH-TU-01000 | 1000 PSI |
| S24EH-TU-02000 | 2000 PSI |
| S24EH-TU-05000 | 5000 PSI |
| S24EH-TU-07500 | 7500 PSI |
| S24EH-TU-10000 | 10000 PSI |
| S24EH-TU-14500 | 14500 PSI |
Proximity Sensor
P/N: B24EH-303015-01
Our products are customized to suit your needs!
|
Manufacturer |
Turck |
| Rated switching distance(Sn) |
10mm |
|
Safe working distance |
≤(0.81 × Sn) mm |
| Correction Factor |
#37 Steel=1; Aluminum=0.3; Stainless Steel=0.7; Brass=0.4 |
|
Repeatability |
≤2% of full scale |
| Temperature Drift |
≤ ±10% |
|
Hysteresis |
1…10% |
| Working Temperature |
-40-+70℃ |
|
Output Performance |
2 lines NAMUR |
| Switching Frequency |
0.5kHz |
|
Voltage |
Nom. 8.2VDC |
| No excitation current loss |
≥2.1mA |
|
Excitation current loss: |
≤1.2mA |
| Compliance certification |
KEMA 02 ATEX 1090X |
|
Design |
Threads,M30×1.5 |
| Size |
44mm |
|
Shell Material |
Plastic, PA12-GF30 |
| Sensing Surface Material |
Plastic,PA12-GF30 |
|
Bottom Cap |
Plastic, Trogamid T |
| Maximum Torque |
5Nm |
|
Cable Material |
φ5.2mm, SiHSi, Silicone Organic Resin, 2m |
| Cable Cross Section |
2×0.5mm² |
|
Anti Vibration |
55Hz(1mm) |
| Impact Resistance |
30g(11ms) |
|
Degree of Protection |
IP67 |
| Box |
170*150*110mm SUS304 |
Temperature & Density sensor
P/N: S24TD-RO-01/02
Temperature & Density Sensor, 4ft / 8ft (Including mounting bracket)
Our products are customized to suit your needs!
|
Part 1 |
|
|
Manufacture |
Emerso |
|
Measurement Range |
Up to 2000 psi (137,89 bar) differential |
|
Up to 2000 psig (137,89 bar) gage |
|
|
Up to 4000 psia (275,79 bar) absolute |
|
|
Process Wetted Material |
316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated 316L SST, Gold-plated Alloy 400 |
|
Diagnostics |
Basic Diagnostics, Process Alerts, Loop Integrity Diagnostics, Plugged Impulse Line Diagnostics |
|
Wireless Update Rate |
1 sec. to 60 min., user selectable |
|
Power Module Life |
Up to 10-year life, field replaceable (order separately) |
|
Wireless Range |
Internal antenna (225 m) |
|
Certifications |
IEC, NSF, NACE®, CSA, CE, ATEX |
| Part 2 | |
| Manufacture | Emerson |
| Seal System Type | Direct Mount, Remote Mount, Tune |
| Transmitter Connection | Welded-Repairable, All Welded |
| Process Connection | Flanged: ANSI/ASME, EN/DIN, GOST, & JIS |
| Threaded: NPT, DIN, ISO | |
| Hygienic | |
| Process Wetted Material | 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST, Corrosion Shield PFA coated 316 SST, see PDS for full list of materials |
| HS P/N | Size(ft) |
| S002104DT | 4 |
| S002108DT | 8 |
Valve position sensor
Application Scenarios:
Technical Specifications:
-
Measurement Range: 0-360 degrees (or as specified for linear models)
-
Accuracy: ±0.5% of full scale
-
Resolution: 0.1% of full scale
-
Output Signal: 4-20 mA, 0-10 V, or digital signal (depending on model)
-
Power Supply: 10-30 VDC (typical)
-
Environmental Rating: IP68, suitable for underwater and harsh industrial environments
-
Temperature Range: -40°C to 150°C (-40°F to 300°F)
-
Pressure Rating: Up to 10,000 psi (depending on model)
-