Showing 1–8 of 9 results

HS ldler Type sensor

P/N: S24HSIT-01
Idler Sensor 1.5 & 1.75 Dbl
Our products are customized to suit your needs!

Name  Manufacturer Type
Idlers HS Sensor Customized processing
Hydraulic cylinder HS Sensor Customized processing
Hydraulic tubing HS Sensor Specification adaptation
Frame HS Sensor Customized processing

 

Integrated Radar Level Sensor

P/N: S24IRL-VG-01

Radar level sensor-4… 20 mA/HART – Two-wire, rod, and rope measuring probes TDR sensors- measures maintenance-free all kinds of liquids, even in applications with vapor, buildup foam generation, and condensation.

Our products are customized to suit your needs!

Features
Manufacturer VEGA
Probe Length 11500mm
Measuring accuracy  ± 2 mm
Certificate ATEX , UKEX
Process Temperature -40-150°C
Electronics Two-wire 4 … 20 mA/HART
Power Supply 9.6 … 35 V DC
 Protection IP66/67
Material Exchangeable cable (ø2mm) with gravity weight /316
Measuring accuracy ± 2 mm
Cable entry / Connection M20x1.5 / Cable gland PA black (ø5-9mm)
Level Sensor Brackets Base Custom

Integrated Ultrasonic Level sensor

P/N: S24IUL-SM-01/02

Integral small range ultrasonic liquid level meter. The two-wire system, 4-20 mA circuit power supply, is suitable for liquids in open or closed containers. Its body size has a maximum range of 5 meters.

Features
Manufacturer SIEMENS
Input Measuring range Frequency: 0.25 … 5 m/12m(0.8 … 16.4 ft)
Frequency: 54 kHz
Output 4 … 20 mA, Proportional/ inversely proportional, 600 Ω in the loop at 24 V DC
Power Supply 12 … 30 V DC, 0.1 A surge 0.75 W (25 mA at 24 V DC)
Certificate CSA, ATEX , UKEX, IECEx , NEPSI Ex
Accuracy Error in measurement:0.25 % of measuring range (in air)
Resolution: 3mm(0.125 inch)
Beam Angle 12°
Ambient Temperature  Standard: -40 … +60 °C (-40 … +140 °F)
Metallic mounting: -20 … +60 °C (-4 … +140 °F)
Weight 1.3 kg (2.9 lb)
Material Electronics enclosure • Transducer: PBT
Transducer: PVDF copolymer
Degree Of Protection Process Connection  IP68 / NEMA 6 / TYPE 6
2″ NPT [(Taper), ASME B1.20.1] • R 2″ [(BSPT), EN 10226]
G 2″ [(BSPP), EN ISO 228-1]
4″ sanitary
Flange Adapter Cable Inlet  3″ Universal (fits DN 65, PN 10 and 3″ ASME) 1 inlet for M20, optional 1/2″ NPT
Level Sensor Brackets Base Custom

 

Mud logging -Flow Sensor

P/N: S24MF-HH-001/020

Mud Flow Sensor Assembly: Included mounting bracket, blind plate, gland, etc.

Our products are customized to suit your needs!

Manufacturer Hohner
Output 4…20 mA 2 wire current loop output
Precision 8 absolute bits / 256 steps、
Per the 90 degrees within 16mA
Equivalent to 1 degree has 0.177mA、0.177mA has 2.84 steps
Operating temp Operating temp: – 20 …+60℃
Weight 26 lbs (12 kg)
Protection IP 66 / X7 M
Materials Encoder Stainless Steel
Material Chassis Stainless Steel
Material Paddles Stainless Steel
Material Spring Stainless Steel
Pressure Rating 5 bar
Note Common design of mounting base.
Certification Zone 0 Ex ia IIC Certified
CE,ATEX, IECEx, CSA,EAC

Pressure Transmitter

P/N: S24EH-TU-00500
Pressure transmitter: (4~20mA),500PSI

Our products are customized to suit your needs!

Features
Pressure Range Relative pressure : 0…500 psi
Admissible overpressure: ≤ 120 bar
Burst pressure:  ≥240 bar
Response time: <2 ms, typ. 1 ms
Long-term stability: 0.25% FS, according to IEC EN 60770-1
Power Supply Operating voltage:10…30 VDC
Current consumption: ≤23 mA
Short-circuit/reverse polarity protection: yes / yes
Protection type and class: IP67 / III
Insulation voltage: 750 VDC
Outputs Output 1: Analog output
Analog Output Current output: 4…20 mA
Operating range: 4…20 mA (2-wire)
Load:≤(Supply voltage -10)/20 kΩ
Resolution: <±0.1 % FS
Accuracy LHR: ± 0.3 % FS BSL
Temperature Behavior Medium temperature: -30…+120 °C
Temperature coefficient: ± 0.2 % of full scale/10 K
Ambient Conditions  Ambient temperature: -25…+85 °C
Storage temperature: -50…+100 °C
Vibration resistance:20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15mm acc. to IEC 68-2-6
Shock resistance:100 g, 11 ms, half sinusoidal curve, all 6 directions,
Free fall from 1 m onto concrete (6x) , acc. to IEC68-2-27

For intrinsically safe applications, the values specified in the corresponding EX certificates (ATEX, IECEX,UL etc.) apply.
Ex approval acc. to conformity certificate: SEV 16 ATEX 0145
Application area: II 1/2 GD
Ignition protection category: Gas Ex ia IIC; dust Ex ia IIIC

HS P/N Pressure
S24EH-TU-01000 1000 PSI
S24EH-TU-02000 2000 PSI
S24EH-TU-05000 5000 PSI
S24EH-TU-07500 7500 PSI
S24EH-TU-10000 10000 PSI
S24EH-TU-14500 14500 PSI

Proximity Sensor Box

P/N: B24EH-303015-01

Our products are customized to suit your needs!

Manufacturer

Turck
Rated switching distance(Sn)

10mm

Safe working distance

≤(0.81 × Sn) mm
Correction Factor

#37 Steel=1; Aluminum=0.3; Stainless Steel=0.7; Brass=0.4

Repeatability

≤2% of full scale
Temperature Drift

≤ ±10%

Hysteresis

1…10%
Working Temperature

-40-+70℃

Output Performance

2 lines NAMUR

Switching Frequency

0.5kHz

Voltage

Nom. 8.2VDC
No excitation current loss

≥2.1mA

Excitation current loss:

 ≤1.2mA
Compliance certification

KEMA 02 ATEX 1090X

Design

Threads,M30×1.5
Size

44mm

Shell Material

Plastic, PA12-GF30
Sensing Surface Material

Plastic,PA12-GF30

Bottom Cap

Plastic, Trogamid T
Maximum Torque

5Nm

Cable Material

φ5.2mm, SiHSi, Silicone Organic Resin, 2m
Cable Cross Section

2×0.5mm²

Anti Vibration

55Hz(1mm)
Impact Resistance

30g(11ms)

Degree of Protection

IP67
Box

170*150*110mm SUS304

Temperature & Density sensor

P/N: S24TD-RO-01/02
Temperature & Density Sensor, 4ft / 8ft (Including mounting bracket)

Our products are customized to suit your needs!

Part 1

Manufacture

Emerso

Measurement Range

Up to 2000 psi (137,89 bar) differential

Up to 2000 psig (137,89 bar) gage

Up to 4000 psia (275,79 bar) absolute

Process Wetted Material

316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated 316L SST, Gold-plated Alloy 400

Diagnostics

Basic Diagnostics, Process Alerts, Loop Integrity Diagnostics, Plugged Impulse Line Diagnostics

Wireless Update Rate

1 sec. to 60 min., user selectable

Power Module Life

Up to 10-year life, field replaceable (order separately)

Wireless Range

Internal antenna (225 m)

Certifications

 IEC, NSF, NACE®, CSA, CE, ATEX

 

Part 2
Manufacture Emerson
Seal System Type Direct Mount, Remote Mount, Tune
Transmitter Connection Welded-Repairable, All Welded
Process Connection Flanged: ANSI/ASME, EN/DIN, GOST, & JIS
Threaded: NPT, DIN, ISO
Hygienic
Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST, Corrosion Shield PFA coated 316 SST, see PDS for full list of materials

 

HS P/N Size(ft)
S002104DT 4
S002108DT 8

 

Valve position sensor

Application Scenarios:

The Valve Position Sensor is a critical component in the oil drilling industry, where precise control and monitoring of valve positions are essential for safety and efficiency. It is used in various applications such as wellhead control systems, flow control systems, and hydraulic systems on drilling platforms and rigs.

Technical Specifications:

  • Measurement Range: 0-360 degrees (or as specified for linear models)
  • Accuracy: ±0.5% of full scale
  • Resolution: 0.1% of full scale
  • Output Signal: 4-20 mA, 0-10 V, or digital signal (depending on model)
  • Power Supply: 10-30 VDC (typical)
  • Environmental Rating: IP68, suitable for underwater and harsh industrial environments
  • Temperature Range: -40°C to 150°C (-40°F to 300°F)
  • Pressure Rating: Up to 10,000 psi (depending on model)
  • Material: Stainless steel for corrosion resistance and durability